High Quality Electro Connecting Pressure Gauge with Ad Hoc

Model NO.: AD hoc
Connection Type: Radial Direction
Function: Local Indication Type, Electric Signal-controlled
Installation Structure: Direct Mounting
Features of Measurement Medium: General Pressure Gauge
Indicating Pressure Reference: General Pressure Gauge
Model Number: Yx-60/Yx-100/Yx150
Working Temperature: -40~70
Trademark: OEM
Transport Package: Export, Carton, Box
Specification: Size: 1.5"(40mm)/50mm/60mm/100mm/150mm/200mm/250mm
Origin: Shandong, China (Mainland)
HS Code: 902620000
Model NO.: AD hoc
Connection Type: Radial Direction
Function: Local Indication Type, Electric Signal-controlled
Installation Structure: Direct Mounting
Features of Measurement Medium: General Pressure Gauge
Indicating Pressure Reference: General Pressure Gauge
Model Number: Yx-60/Yx-100/Yx150
Working Temperature: -40~70
Trademark: OEM
Transport Package: Export, Carton, Box
Specification: Size: 1.5"(40mm)/50mm/60mm/100mm/150mm/200mm/250mm
Origin: Shandong, China (Mainland)
HS Code: 902620000
     High Quality Electric Contact Melt Pressure Gauge with AD hoc
High Quality Electro Connecting Pressure Gauge with Ad Hoc
 
  Model         Pressure range               Accuracy             Connection
           YX-60(Z/ZT)

0 ~ ( 0.1/ 0.16/ 0.25/ 0.4/ 0.6/ 1/ 1.6/ 2.5/ 4/ 6/ 10/ 16/ 25/ 40/ 60 )

2.5 BSP ; NPT ; PF
           YX-100(Z/ZT)

0 ~ ( 0.1/ 0.16/ 0.25/ 0.4/ 0.6/ 1/ 1.6/ 2.5/ 4/ 6/ 10/ 16/ 25/ 40/ 60/ 100 )

-0.1 ~ ( 0/ 0.15/ 0.3/ 0.5/ 0.9/ 1.5/ 2.4 )

1.6 BSP ; NPT ; PF
           YX-150(Z/ZT)

0 ~ ( 0.1/ 0.16/ 0.25/ 0.4/ 0.6/ 1/ 1.6/ 2.5/ 4/ 6/ 10/ 16/ 25/ 40/ 60/ 100 )

-0.1 ~ ( 0/ 0.15/ 0.3/ 0.5/ 0.9/ 1.5/ 2.4 )

1.6 BSP ; NPT ; PF

High Quality Electro Connecting Pressure Gauge with Ad Hoc
Dia: φ50/60/100/150/200/250mm
 
Accuracy grade: 0.4/1.0/1.5/1.60/2.0%
Working pressure: The pressure gauge should not
exceed 3/4 of the maximun scale
value under steady pressure and
not exceed 2/3 of the maximum
scale value under fluctuation
pressure and not exceed 1/3 of
the maximum scale value under
shori-time pressure
Max power: 50VA
Working Voltage: DC24V,AC220V or AC380V
Control method: top and bottom limitation,contact switch,dry reed
IP grade: IP65
Connection Thread: M20×1.5,PF(PT,NPT)1/2
Damping fluid: Silicon oil△
Bourdon tube: brass sus304 or sus316
Connection
material:
tin alloys, sus304 or sus316
 
Movement: SUS304, copper alloy
  Casing: SUS304, Steel plate chrome plated
  Glass: PC

  Verification

 1. Electric contact pressure gauge is actually gauge control circuit switch,
is only one more on normal pressure gauge electric contact signal device,
as a result, the pressure of calibration and verification of ordinary pressure
gauge is the same, only a partial certified pressure, still need to increase the
verification for the electric contact signal device.

 2. Steps for the verification of electric contact pressure gauges.

 The pressure gauge is mounted on the calibrator, and the two signal contact
pointer is set to the upper limit and lower limit by the dial needle, and then the
indicator test is carried out.Certified value, the upper and lower limits of the signal
contact pointer is scheduled for more than three different check point, slowly
increase or reduce the pressure, until the signal instantaneous, the standard
pressure gauge readings and signal pointer value, the deviation between the
absolute value of basic error must not exceed the allowed.

 FAQ processing

 

 The electrical contact pressure gauge may signal too early or too late:

 It is the position of the contact or the metal rod loose.The contact position is not
positive, and the contact is calibrated vertically to the appropriate signal.
 Contact metal rod looseness, should try to consolidate, slightly, use the appropriate amplification of the wire, increase the anti-torque of the silk, also have the effect.

 Electrical contact device does not signal: contact is too dirty contact;The insulation
layer of the signal device is damp;Circuit failure, etc.The contact is too dirty, sanded
with sandpaper to remove the dirt;The insulation layer is damp and dry with hot air;
The circuit is blocked and should be found and repaired.

High Quality Electro Connecting Pressure Gauge with Ad Hoc
  Details of the products produced by our own factory.
 There are advanced pressure detector and careful worker, the quality is assured,
please feel free to order.


High Quality Electro Connecting Pressure Gauge with Ad Hoc
  One of three biggest pressure gauge manufacturers in China ,
established in 1987, Qingdao Hakin Group Co., Ltd. Specializes in 
manufacturing and exporting Pressure gauge, Pressure regulator, 
Manometer and Pressure thermometer. 
 We have a strong network that allows us to design and customize 
products. We currently produce over 8 varieties, more than 100 series, 
and about 1, 000 specifications of instruments for various industries 
including oil exploration, chemical industry, chemical fiber industry, 
iron and steel industry, metallurgical industry, power generation plants, 
food industry and scientific research. 
 Our products are exported to East Asia such as Korea & Japan, the 
European Union such as Russia, Germany & Italy,and the Middle East, 
America. Southeast Asia such as Vietnam, Thailand & Indonesia. 
 Our company's main partners: Italian TER. MA. DEN. SNC, South Korea, 
Germany WIKA, China's Haier. 
 As a well-known manufacturer in China, our factory has approved by 
CCC, ISO14001, ISO9001, CE, SGS and KS certificates. 
 We will unswervingly make more efforts to supply competitive products 
and the best services to all customers. 
 If you need high quality products, wecome to contact us. 
 Once cooperation, friends forever.

High Quality Electro Connecting Pressure Gauge with Ad Hoc

High Quality Electro Connecting Pressure Gauge with Ad Hoc

     High Quality Electric Contact Melt Pressure Gauge with AD hoc
High Quality Electro Connecting Pressure Gauge with Ad Hoc
 
  Model         Pressure range               Accuracy             Connection
           YX-60(Z/ZT)

0 ~ ( 0.1/ 0.16/ 0.25/ 0.4/ 0.6/ 1/ 1.6/ 2.5/ 4/ 6/ 10/ 16/ 25/ 40/ 60 )

2.5 BSP ; NPT ; PF
           YX-100(Z/ZT)

0 ~ ( 0.1/ 0.16/ 0.25/ 0.4/ 0.6/ 1/ 1.6/ 2.5/ 4/ 6/ 10/ 16/ 25/ 40/ 60/ 100 )

-0.1 ~ ( 0/ 0.15/ 0.3/ 0.5/ 0.9/ 1.5/ 2.4 )

1.6 BSP ; NPT ; PF
           YX-150(Z/ZT)

0 ~ ( 0.1/ 0.16/ 0.25/ 0.4/ 0.6/ 1/ 1.6/ 2.5/ 4/ 6/ 10/ 16/ 25/ 40/ 60/ 100 )

-0.1 ~ ( 0/ 0.15/ 0.3/ 0.5/ 0.9/ 1.5/ 2.4 )

1.6 BSP ; NPT ; PF

High Quality Electro Connecting Pressure Gauge with Ad Hoc
Dia: φ50/60/100/150/200/250mm
 
Accuracy grade: 0.4/1.0/1.5/1.60/2.0%
Working pressure: The pressure gauge should not
exceed 3/4 of the maximun scale
value under steady pressure and
not exceed 2/3 of the maximum
scale value under fluctuation
pressure and not exceed 1/3 of
the maximum scale value under
shori-time pressure
Max power: 50VA
Working Voltage: DC24V,AC220V or AC380V
Control method: top and bottom limitation,contact switch,dry reed
IP grade: IP65
Connection Thread: M20×1.5,PF(PT,NPT)1/2
Damping fluid: Silicon oil△
Bourdon tube: brass sus304 or sus316
Connection
material:
tin alloys, sus304 or sus316
 
Movement: SUS304, copper alloy
  Casing: SUS304, Steel plate chrome plated
  Glass: PC

  Verification

 1. Electric contact pressure gauge is actually gauge control circuit switch,
is only one more on normal pressure gauge electric contact signal device,
as a result, the pressure of calibration and verification of ordinary pressure
gauge is the same, only a partial certified pressure, still need to increase the
verification for the electric contact signal device.

 2. Steps for the verification of electric contact pressure gauges.

 The pressure gauge is mounted on the calibrator, and the two signal contact
pointer is set to the upper limit and lower limit by the dial needle, and then the
indicator test is carried out.Certified value, the upper and lower limits of the signal
contact pointer is scheduled for more than three different check point, slowly
increase or reduce the pressure, until the signal instantaneous, the standard
pressure gauge readings and signal pointer value, the deviation between the
absolute value of basic error must not exceed the allowed.

 FAQ processing

 

 The electrical contact pressure gauge may signal too early or too late:

 It is the position of the contact or the metal rod loose.The contact position is not
positive, and the contact is calibrated vertically to the appropriate signal.
 Contact metal rod looseness, should try to consolidate, slightly, use the appropriate amplification of the wire, increase the anti-torque of the silk, also have the effect.

 Electrical contact device does not signal: contact is too dirty contact;The insulation
layer of the signal device is damp;Circuit failure, etc.The contact is too dirty, sanded
with sandpaper to remove the dirt;The insulation layer is damp and dry with hot air;
The circuit is blocked and should be found and repaired.

High Quality Electro Connecting Pressure Gauge with Ad Hoc
  Details of the products produced by our own factory.
 There are advanced pressure detector and careful worker, the quality is assured,
please feel free to order.


High Quality Electro Connecting Pressure Gauge with Ad Hoc
  One of three biggest pressure gauge manufacturers in China ,
established in 1987, Qingdao Hakin Group Co., Ltd. Specializes in 
manufacturing and exporting Pressure gauge, Pressure regulator, 
Manometer and Pressure thermometer. 
 We have a strong network that allows us to design and customize 
products. We currently produce over 8 varieties, more than 100 series, 
and about 1, 000 specifications of instruments for various industries 
including oil exploration, chemical industry, chemical fiber industry, 
iron and steel industry, metallurgical industry, power generation plants, 
food industry and scientific research. 
 Our products are exported to East Asia such as Korea & Japan, the 
European Union such as Russia, Germany & Italy,and the Middle East, 
America. Southeast Asia such as Vietnam, Thailand & Indonesia. 
 Our company's main partners: Italian TER. MA. DEN. SNC, South Korea, 
Germany WIKA, China's Haier. 
 As a well-known manufacturer in China, our factory has approved by 
CCC, ISO14001, ISO9001, CE, SGS and KS certificates. 
 We will unswervingly make more efforts to supply competitive products 
and the best services to all customers. 
 If you need high quality products, wecome to contact us. 
 Once cooperation, friends forever.

High Quality Electro Connecting Pressure Gauge with Ad Hoc

High Quality Electro Connecting Pressure Gauge with Ad Hoc

Section Steel Products

Section Steel Products,Steel Shapes,Structural Steel Shapes,Rectangular Tube Steel

Shandong Rizhaoxin Metal Products Co., Ltd. , https://www.sdrizhaoxinsteel.com