Model NO.: JH-LWGY-T
Measuring Media: Liquid
Measuring Principle: Mechanics
Measurement Object: Closed Pipeline
Certification: CE, ISO
Display: LCD
Temperature: -20c~120c
Power Supply: 24VDC or Battery
Output Signal: Pulse, 4-20mA
Body Materia: Ss304/Ss316
Connection: Flange or Screw Thread
Trademark: JH
Transport Package: Carton/Wooden Case
Specification: CE, ISO
Origin: Shanghai
HS Code: 9026100000
Liquid Turbine Flowmeter


Â
Main Applications:Turbine flow flowmeter adapts to measure the liquid rate and total flow rate of low viscosity, It can be widely used in the fields of Petrol,fuel ,water ,chemical industry,Metallurgy,Scientific research for measuring or control Several output and display methods can be selected.Â
Features:-Accuracy reaching ±1.0%F·S.
-Short-term repeatability reaching 0.05%~0.2%.
-Output pulse frequency signal, which is suitable for gross metering and connection to the computer. No zero drift and strong anti-interference capability.
-3-4kHz frequency signal , and high signal resolution.
-Wide range with 1:20 for medium and large caliber, 1:10 for small caliber.
-Compact and light structure, convenient installation and maintenance, great capability.
-Suitable for measuring high pressure. Easy to be made into high-pressure meter.
-Various kinds of specified sensors.Â
Technical parameters:Table 3-1
Nominal Diameter DN(mm)
|
Range(m3/h) |
Liquid Temperature (ºC)
|
Nominal Pressure PN(MPa)
|
Ambient Temp. (ºC)
|
Humidity (%)
|
Max. Pressure Loss (MPa)
|
Error  0.2%*
|
Error   0.5% |
Error     1% |
Min. |
Max. |
Min. |
Max. |
Min. |
Max. |
2*
|
 |
 |
 |
 |
0.03 |
0.16 |
-20 Â to +120 |
6.3 |
-25 to +55 |
≤ 80 |
0.15 |
4*
|
 |
 |
 |
 |
0.04 |
0.25 |
0.12 |
6 |
 |
 |
0.1 |
0.6 |
0.1 |
0.6 |
6.3 16 25 32* |
0.08 |
10 |
 |
 |
0.25 |
1.2 |
0.2 |
1.2 |
0.05 |
15 |
1.2 |
6 |
0.6 |
4 |
0.6 |
6 |
0.035 |
25 |
2 |
10 |
1.6 |
10 |
1 |
10 |
40 |
4 |
20 |
3 |
20 |
2 |
20 |
1.6 2.5 |
0.025 |
50 |
6 |
40 |
4 |
40 |
4 |
40 |
80 |
16 |
100 |
10 |
100 |
10 |
100 |
100 |
25 |
160 |
20 |
160 |
20 |
200 |
1.6 2.5 |
150 |
50 |
300 |
40 |
300 |
40 |
400 |
200 |
150 |
750 |
100 |
600 |
80 |
800 |
250*
|
200 |
1000 |
160 |
1000 |
120 |
1200 |
1.6 |
300*
|
 |
 |
260 |
1600 |
180 |
1800 |
Note: "*" means special order
Â
Table 3-2 Model and Specification Code
Model |
Specification Code |
Description |
LW....................................................................................... |
Turbine Flowmeter Transducer For Liquid |
 |
G........................................................................ |
 |
Y...................... |
Nominal Diameter |
-2*................................................. -4*................................................. -6.................................................. -10................................................ -15................................................ -25................................................ -40................................................ -50................................................ -80................................................ -100.............................................. -150.............................................. -200.............................................. -250.............................................. -300.............................................. |
2mm(PT G3/8″) 4mm(PT G3/8″) 6mm(PT G3/8″) 10mm(PT G1/2″) 15mm(PT G1″) 25mm(PT G11/4″) 40mm(Flange) 50mm(Flange) 80mm(Flange) 100mm(Flange) 150mm(Flange) 200mm(Flange*) 250mm(Flange*) 300mm(Flange) |
Type Code |
A............................ .......... B............................ .......... C............................ ....... |
Accuracy 1% Accuracy 0.5% Accuracy 0.2%*
|
Output Signal |
P......................... ....... I.......................... ....... T......................... ....... M........................ ....... |
Pulse Analog 4 to 20mA Total display(Battery. for 2 to 3 years) Pulse out/4 to 20mA out and LCD display(Intelligent) |
Diameter Pressure |
C1................... ..... C2................... ..... C3................... ..... C4................... ..... C5................... ..... C6................... ..... C7................... ..... |
PN1.6MPa PN2.5MPa PN4.0MPa PN6.3MPa PN16MPa(Diameter≤25mm) PN25MPa(Diameter≤25mm) PN40MPa*(Diameter≤25mm)
|
Explode Request |
/NE /EX |
Not Explosive Ex ib I or Ex dIIBT4 |
Range of Temperature |
/NT /HT |
Normal Temperature(<120ºC) High Temperature(≥120 to 150ºC) |
Special Option |
/ |
e.g.:High Temperature,Erode-resistant,Wearable etc. |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
   Â
 Note:1. The dimensions of connecting flange are in accordance with DIN             2. Mark "*" means special order.Â
Plastic Agglomerator
Plastic Agglomerator is widely used for film or fiber recycling, it used for recycling machine industry, it can recycle PET flakes,LDPE,LLDPE,HDPE, PE, PP film and woven bags . It can also used for plastic PE PP recycling granulator line.
When the waste plastic is supplied into the chamber of such machine, it will be cut into smaller chips due to the crushing
function of the rotating knife and fixed knife. During the crushing processing, the material that soaked up lots heat from the frictional movement of material being crushing and the wall of container will be going to become semi-plasticizing state. The particles will stick with each other due to the function of plasticization. Before it sticks each other completely, the cold water pre-prepared is sprayed into the material being crushed. The water will be evaporated off quickly and the surface temperature of material being crushed drop down quickly also. So the material being crushed will become small particles or granules. It is easy to recognize the particles by different size and can be colored by using of color agent being putted into the container during the crushing processing.
Plastic Agglomerator,plastic agglomerate,Plastic Agglomerator Machine,Plastic Pelletizer
zhangjiagang sevenstars machinery co.,ltd , https://www.sevenstars-machineries.com